Dynamic Voltage Restorer
In the power transmission system, when the grid voltage disturbance moment or load faults such as short circuit and so on, will branch voltage sensitive load caused by falling, rising and other issues; this change is very lethal to such as semiconductor manufacturing factory, due to problems caused by the voltage sudden loss of tens of thousands each year. The purpose of DVR is to compensate for the short time voltage drop and rise. It adjusts the voltage quality of the user terminal by introducing a voltage source into the distribution system to suppress the impact of voltage disturbance on the sensitive load of the distribution system.

In the power transmission system, when the grid voltage disturbance moment or load faults such as short circuit and so on, will branch voltage sensitive load caused by falling, rising and other issues; this change is very lethal to such as semiconductor manufacturing factory, due to problems caused by the voltage sudden loss of tens of thousands each year. The purpose of DVR is to compensate for the short time voltage drop and rise. It adjusts the voltage quality of the user terminal by introducing a voltage source into the distribution system to suppress the impact of voltage disturbance on the sensitive load of the distribution system.




Product Features:

Human-computer interface
Humanized interface, let your operation be handy!


     
Intelligent display and diagnosis system, including working state, three phase voltage, three phase current, fault display and parameter setting, can be set by LCD and keyboard, and the operation is simple.

Use as UPS

Full power compensation and isolation DVR can be connected to external batteries. When online UPS is used, it is necessary to increase battery charging and monitoring module. If necessary, please specify when ordering.

It not only has the function of UPS's continuous power supply, but also has strong ability to resist interference from input power, and solves the harsh requirements of ordinary UPS to the input power environment.



Input voltage 3Ф380V±20%(3 phase 4 lines)(permitted short drop 50%)
Input frequency 40-70Hz
Output voltage 3Ф380V±5%(Adjustable)
Voltage stablity accuracy ±1%
Main control part IGBT
Compensated mode MPWM,inverter compensation(inverter inside)
Compensated time ≤2ms
Harmonic wave compensated voltage THD≤2%
Voltage adjustable mode 3 phase adjusting respectively,3 phase auto balance
Harmonic wave resistance Able to work under serious wave distortion.
Sharp peek resistance Input 4000V single pulse,output less than 40V
Wave filter

0.15M—10M,differential mode 70—100dB,common mode 100dB。

DVR Dynamic Voltage Restorer(3 phase output)

Model

Capacity
(KVA)

Output current
(A)

Dimension
W×T×H(mm)

Model

Capacity
(KVA)

Output current
(A)

Dimension
W×T×H(mm)

DVR13003
DVR33003

3

4.2

350×650×670
(with wheels)

DVR33150

150

228

1200×750×1800

DVR33200

200

304

DVR13006
DVR33006

6

8.4

DVR33250

250

380

1400×800×2000

DVR33300

300

456

DVR13010
DVR33010

10

15

DVR33350

350

532

1500×1050×2200

DVR33400

400

608

DVR13015
DVR33015

15

23

460×700×1170
(with wheels)

DVR33500

500

760

2400×1200×2200

DVR33600

600

912

DVR13020
DVR33020

20

30

DVR33800

800

1216

1500×1050×2200
(2 machines in a carbin)

DVR331000

1000

1520

DVR33030

30

45

DVR331200

1200

1823

1500×1050×2200
(3 machines in a carbin)

DVR33045

45

68

780×650×1450

DVR331400

1400

2127

DVR33060

60

91

DVR331600

1600

2431

1500×1050×2200
(4 machines in a carbin)

DVR33075

75

114

950×700×1600

DVR331800

1800

2735

DVR33090

90

137

DVR332000

2000

3038

DVR33120

120

183

DVR333000

3000

4558

1500×1050×2200
(6 machines in a carbin)

 

DVR Dynamic Voltage Restorer(Single output)

Model

Capacity
(KVA)

Output current 
(A)

Dimension
W×T×H(mm)

Model

Capacity
(KVA)

Output current(A)

Dimension
W×T×H(mm)

DVR11-500W

0.5

4.2

425×436×173
4U highness

DVR11045
DVR31045

45

189

780×650×1450

DVR11001

1

4.2

DVR11002

2

8.5

350×650×670
(with wheels)

DVR31060

60

252

DVR11003

3

13

DVR31075

75

315

950×700×1600

DVR11005

5

21

DVR31090

90

378

DVR11010
DVR31010

10

42

DVR31120

120

504

1200×750×1800

DVR11015
DVR31015

15

63

460×700×1170
(with wheels)

DVR31150

150

630

DVR11020
DVR31020

20

84

DVR31200

200

840

1400×800×2000

DVR11030
DVR31030

30

126

DVR31300

300

1350

It is suitable for the power grid with serious interference source and high harmonic distortion. For example, the interference caused by the nonlinear load of steel-making furnace, the frequent start up disturbance of the induction motor in the factory, the voltage rise, the temporary drop and the harmonic disturbance generated by the heavy load of high speed rail and rail transit. A power supply for high density equipment. For example, communication equipment, laser processing machine, precision punching machine, CNC machining center, the production line etc..